38
ATR
O
2
N
2
TO SET - DIVE TIME REMAINING ALARM
(while in the Surface Mode)
Factory set for 5 minutes, the Dive Time Remaining Alarm
can be set to values between 0:00 and 0:20 (minutes) in
increments of 1 minute.
• Press Both buttons simultaneously, release when SET: 2
appears (4 seconds).
• Press and release the Left (Advance) button, the Units
screen appears with the set point flashing.
• Press the Left (Advance) button 12 more times.
• The graphic dtr, and Alarm (speaker) and Dive Mode
icons appear with the Dive Time Remaining value
flashing (Fig. 36).
• Press and hold the Right (Select) button to scroll through
the Alarm values in increments of one minute.
• Press the Left (Advance) button to accept the setting and
advance to Set Max PO2 Alarm, or press and hold Both
buttons for 2 seconds to revert to Surface Mode.
Fig. 36 - Set Dive Time
Remaining Alarm